IR Moisture Sensor
Online surface moisture measurement
Key Features
- Non-contact, single sided online measurement
- Liquid cooled head platform for better long-term reliability
- More accurate online measurements with less calibration needs
- Dust trap before lens to keep it free from steam and dust
- More accurate online measurements using large optical components
Measuring Method
The Scienta NIR absorption-based sensor series 7230 is a double sided, 2-channel or 4-channel InGaAs detector-based Moisture weight sensor for online use. The sensor measures the infrared light absorbed by different wavelengths caused by the water on sheet. This signal is digitalized and linearized to correlate to real weights in engineering units. Moisture range is 1 – 35 %. Paper weight range is 5..350 g/m².
Benefits
To process applications such as paper moisture, corrugated board warp control & pulp drying water management, laminating, paper surface moisture etc.
- No radioactive source is required
- Non-contact measurement
- Service free construction
- Easy and convenient to install and operate
- Full range of scanners available
- Easy calibration and setup
- More accurate online measurements
- Faster on-spec quality and reduced start up waste
- Faster on-spec quality and reduced start up waste
- Reduction in rejects due to high performing measurements
- Measurement before size press is possible using liquid cooling option
- Machine speeds can be increased on drying limited pulp and paper machines
- Spectrometer with 128 channels available
Technical Specifications
Sensor Type | 7230-2 | 7235-2 |
Construction | Double sided | Single sided |
MEAS Channels | 2,4, 128 | 2 |
Moisture Range | 5–350 gms, 1–35 % | 1 – 70 % |
Accuracy | 0,1% | 0,2% |
Repeatability | 0,01% | 0,01% |
Reccomended Measurement gap | 13 mm | 100 mm |
Power | +24V, 1A | +24V, 1A |
Installation | Scanning /Fixed | Scanning /Fixed |
Sensor Type | 7230-2 | 7235-2 |
Ambient light sensitivity | None | None |
Interface Options | Profibus | Profibus |
Modbus | Modbus | |
Ethernet | Ethernet | |
USB | USB | |
Local PLC | Yes | Yes |
Environmental Conditions | 10-60 ℃ 10-95 % RH | 10-60 ℃ 10-95 % RH |
Liquid Cooling | Optional | Optional |